Performance evaluation and calibration of capacitance sensor for estimating the salinity of reclaimed land

Donggeun Kim, Younghwan Son, Jaesung Park, Taejin Kim, Jihun Jeon

Abstract


Generally, soil moisture and salinity in reclaimed land are monitored using soil dielectric sensors such as time domain reflectometry, frequency domain reflectometry, and capacitance. The soil dielectric sensor measures apparent dielectric permittivity. However, apparent dielectric permittivity is affected by soil moisture, salinity, and texture. In this study, performance evaluation and calibration of a dielectric sensor (5TE; METER Group, Inc., Pullman, WA, USA) for monitoring soil salinity were performed. Laboratory calibration tests were completed, incorporating various levels of dry density, water content, and salinity. The soil salinity was determined by the electrical conductivity (EC)1:5 method. The volumetric water content as measured by the sensor was affected by dry density and water content. Generally, it linearly increased as dry density and water content increased. However, when dry density or water content was high, the measured value of the sensor increased nonlinearly. The bulk EC measured by sensor had no specific correlation with EC1:5. The EC1:5 measurement had a linear relationship with the gradient of θ and θs. Therefore, it can be estimated with a simple linear equation using θ from the soil test and θs from the capacitance sensor. The R2 value of the EC1:5 estimation equation was 0.98. The proposed equation requires θ from the gravimetric sample and θs from the sensor. Therefore, in the case of monitoring salinity using a sensor, it is recommended to measure the water content with a tensiometer.
Keywords: salinity, capacitance sensor, volumetric water content, reclaimed land soil, saline soil
DOI: 10.25165/j.ijabe.20201301.3905

Citation: Kim D, Son Y, Park J, Kim T, Jeon J. Performance evaluation and calibration of capacitance sensor for estimating the salinity of reclaimed land. Int J Agric & Biol Eng, 2020; 13(1): 206–210.

Keywords


salinity, capacitance sensor, volumetric water content, reclaimed land soil, saline soil

Full Text:

PDF

References


Morales M A, Olmos E, Torrecillas A, Sánchez-Blanco M J, Alarcon J J. Differences in water relations, leaf ion accumulation and excretion rates between cultivated and wild species of Limonium sp. grown in conditions of saline stress. Flora, 2001; 196(5): 345–352.

Valdés R, Ochoa J, Franco J A, Sánchez-Blanco M J, Bañón S. Saline irrigation scheduling for potted geranium based on soil electrical conductivity and moisture sensors. Agricultural Water Management, 2015; 149: 123–130.

Morgan K T, Parsons L R, Wheaton T A. Comparison of laboratory-and field-derived soil water retention curves for a fine sand soil using tensiometric, resistance and capacitance methods. Plant and Soil, 2001; 234(2): 153–157.

Visconti F, de Paz J M, Martínez D, Molina M J. Laboratory and field assessment of the capacitance sensors Decagon 10HS and 5TE for estimating the water content of irrigated soils. Agricultural Water Management, 2014; 132: 111–119.

Robinson D A, Campbell C S, Hopmans J W, Hornbuckle B K, Jones S B, Knight R, et al. Soil moisture measurement for ecological and hydrological watershed-scale observatories: A review. Vadose Zone Journal, 2008; 7(1): 358–389.

Skierucha W, Wilczek A. A FDR sensor for measuring complex soil dielectric permittivity in the 10–500 MHz frequency range. Sensors, 2010; 10(4): 3314–3329.

Robock A, Vinnikov K Y, Srinivasan G, Entin J K, Hollinger S E, Speranskaya N A, et al. The global soil moisture data bank. Bulletin of the American Meteorological Society, 2000; 81(6): 1281–1299.

Dobriyal P, Qureshi A, Badola R, Hussain S A. A review of the methods available for estimating soil moisture and its implications for water resource management. Journal of Hydrology, 2012; 458–459: 110–117.

Topp G C. State of the art of measuring soil water content. Hydrological Processes, 2003; 17(14): 2993–2996.

Topp G C, Davis J L, Annan A P. Electromagnetic determination of soil water content: Measurements in coaxial transmission lines. Water Resources Research, 1980; 16(3): 574–582.

Topp G C, Zegelin S, White I. Impacts of the real and imaginary components of relative permittivity on time domain reflectometry measurements in soils. Soil Science Society of America Journal, 2000; 64(4): 1244–1252.

He Y B, DeSutter T, Hopkins D, Jia X H, Wysocki D A. Predicting ECe of the saturated paste extract from value of EC1: 5. Canadian Journal of Soil Science, 2013; 93(5): 585–594.

Longenecker D E, Lyerly P J. Making soil pastes for salinity analysis: A reproducible capillary procedure. Soil Science, 1964; 97(4): 268–275.

Khorsandi F, Yazdi F A. Gypsum and texture effects on the estimation of saturated paste electrical conductivity by two extraction methods. Communications in Soil Science and Plant Analysis, 2007; 38(7-8): 1105–1117.

Rayment G, Higginson F R. Australian laboratory handbook of soil and water chemical methods: Inkata Press Pty Ltd, 1992.

Shirokova Y, Forkutsa I, Sharafutdinova N. Use of electrical conductivity instead of soluble salts for soil salinity monitoring in Central Asia. Irrigation and Drainage Systems, 2000; 14(3): 199–206.

Hilhorst M A. A pore water conductivity sensor. Soil Science Society of America Journal, 2000; 64(6): 1922–1925.

Meter Group. 5TE Operator’s manual. Pull man: Meter group, Inc. 2018. http://publications.metergroup.com/Manuals/20435_5TE_Manual_Web.pdf. Accessed on [2018-04-24]

Kargas G, Soulis K X. Performance analysis and calibration of a new low-cost capacitance soil moisture sensor. Journal of Irrigation and Drainage Engineering, 2012; 138(7): 632–641.

Rosenbaum U, Huisman J A, Weuthen A, Vereecken H, Bogena H R. Sensor-to-sensor variability of the ECH2O EC-5, TE, and 5TE sensors in dielectric liquids. Vadose Zone Journal, 2010; 9(1): 181–186.

Scudiero E, Berti A, Teatini P, Morari F. Simultaneous monitoring of soil water content and salinity with a low-cost capacitance-resistance probe. Sensors, 2012; 12(12): 17588–17607.

Kizito F, Campbell C S, Campbell G S, Cobos D R, Teare B L, Carter B, et al. Frequency, electrical conductivity and temperature analysis of a low-cost capacitance soil moisture sensor. Journal of Hydrology, 2008; 352(3-4): 367–378.

Varble J L, Chávez J L. Performance evaluation and calibration of soil water content and potential sensors for agricultural soils in eastern Colorado. Agricultural Water Management, 2011; 101(1): 93–106.




Copyright (c) 2020

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

2023-2026 Copyright IJABE Editing and Publishing Office